The report describes an RF cell culture irradiation system with controlled temperature and field strength that can produce electric field strengths up to 100 V/cm from D.C. to 1000 MHz in a 5-ml sample of culture medium.

Plain English Summary

Summary written for general audiences

The system was designed for the National Institute for Occupational Safety and Health to determine human RF exposure thresholds in the frequency range D.C. to 100 MHz. The final design uses concentric stainless steel rings with a teflon bottom that forms a liquid-tight seal compressed by brass retainer clamps.

Why This Matters

The initial design was unsuccessful because high input impedance made it difficult to couple power to the culture medium and more power was absorbed by the coolant than the culture. The final system allows accurate dosimetry through vector voltmeter measurements processed by a programmable Hewlett-Packard 65 calculator in seconds. The system can operate at frequencies up to 1 GHz and is useful for determining whether observed effects in vitro are athermal or thermal in nature.

Exposure Details

SAR
200 W/kg
Electric Field
100 V/cm

Exposure Context

This study used 100 V/cm for electric fields:

This study used 200 W/kg for SAR (device absorption):

Building Biology guidelines are practitioner-based limits from real-world assessments. BioInitiative Report recommendations are based on peer-reviewed science. Check Your Exposure to compare your own measurements.

Where This Falls on the Concern Scale

Study Exposure Level in ContextStudy Exposure Level in ContextThis study: 200 W/kgExtreme Concern - 0.1 W/kgFCC Limit - 1.6 W/kgEffects observed in the Extreme Concern range (Building Biology)This level is 125 times the FCC limit
A logarithmic frequency spectrum from 10 Hz to 100 GHz showing where this study's 0 Hz to 1 GHz exposure sits relative to common EMF sources.Where This Frequency Sits on the EMF SpectrumELFVLFLF / MFHF / VHFUHFSHFmm10 Hz100 GHzThis study: 0 Hz to 1 GHzPower lines50/60 HzCell phones~1 GHzWiFi2.4 GHz5G mm28 GHzLogarithmic scale
Cite This Study
Arthur W. Guy (1977). RF Cell Culture Irradiation System with Controlled Temperature and Field Strength.
Show BibTeX
@article{rf_cell_culture_irradiation_system_with_controlled_temperature_and_field_strengt_g4420,
  author = {Arthur W. Guy},
  title = {RF Cell Culture Irradiation System with Controlled Temperature and Field Strength},
  year = {1977},
  
  
}
No DOI on file for this study.

Quick Questions About This Study

The system was designed for the National Institute for Occupational Safety and Health to determine human RF exposure thresholds in the frequency range D.C. to 100 MHz.
The system can produce electric field strengths up to 100 V/cm from D.C. to 1000 MHz in a 5-ml sample of culture medium.
Temperature is controlled and measured up to 100 MHz by monitoring feedline impedance, which depends on culture medium temperature, and a heat exchanger maintains constant temperatures below 37° C at field strengths exceeding 25 V/cm.
The final design uses two concentric stainless steel ring walls with a flat annular teflon ring bottom that forms a liquid-tight seal compressed by brass retainer clamps, and a teflon cap with pressure release and thermocouple access.
Accurate dosimetry is maintained through measurements made with a vector voltmeter, and complete dosimetry information can be obtained in seconds using a programmable Hewlett-Packard 65 hand-held calculator.