Kumari K et al. · 2017
Researchers exposed mice to 7.5 kHz magnetic fields at 12 or 120 μT for 5 weeks. No effects were seen on body weight, spontaneous activity, motor coordination, anxiety, or aggression. In the Morris swim task, the 120 μT group showed a less steep learning curve than other groups. The passive avoidance task revealed a clear memory impairment over 48 hours in the 120 μT group. Hippocampal astroglial activation and neurogenesis were unchanged, while tumor necrosis factor alpha mRNA increased significantly in the 120 μT group.
Marjanovic Cermak AM et al. · 2017
Researchers exposed human cells to cell phone radiation (1800 MHz) for up to 60 minutes at typical phone power levels. The cells showed signs of oxidative stress, including increased harmful free radicals and elevated cellular defense responses, even without heating effects.
Poulletier de Gannes F et al. · 2017
Kumari K et al. · 2017
Researchers exposed mice to 7.5 kHz magnetic fields (the frequency used in electronic security systems and induction cooktops) for 5 weeks and found memory impairment at higher exposure levels. Mice exposed to 120 μT showed slower learning and poorer memory retention after 48 hours, along with increased brain inflammation markers.
Kumari K et al. · 2017
Researchers exposed mice to 7.5 kHz magnetic fields for 5 weeks and found that higher exposure levels (120 μT) impaired learning and memory abilities. The mice showed slower learning in maze tests and memory problems after 48 hours, along with increased brain inflammation markers. This suggests intermediate frequency magnetic fields from common devices like induction cooktops may affect cognitive function.
Kumari K et al. · 2017
Researchers exposed mice to 7.5 kHz magnetic fields from sources like electronic security systems and induction cooktops for 5 weeks. At higher exposure levels (120 μT), mice showed memory problems and brain inflammation markers, while lower levels (12 μT) had no effect. This suggests intermediate frequency magnetic fields may impair learning through inflammatory brain responses.
Davarpanah Jazi S, Modolo J, Baker C, Villard S, Legros A. · 2017
Ten healthy volunteers were exposed to 11 MF conditions (60 Hz, 0 to 50 mTrms, 5 mTrms increments) while physiological tremor and EEG from motor and somatosensory brain regions were measured. Exposure had no significant effect on any physiological tremor characteristics, and no significant EEG effects were observed for electrodes C1, C3, C5 and CP1. At electrodes CP3 and CP5, a decreased mu-rhythm spectral power with increasing MF flux density was suggested, but this was not confirmed by Bonferroni corrected pairwise comparisons.
Lian HY, Lin KW, Yang C, Cai P. · 2017
Researchers exposed two budding yeast strains, NT64C and SB34, to 2.0 GHz RF-EMF and 50 Hz ELF-EMF. Both RF-EMF and ELF-EMF exposure elevated the de novo generation and propagation of the yeast prion [URE3] in the two strains. The increase grew over time, and ELF-EMF showed a dose-dependent effect. Chaperone transcription and expression (Hsp104, Hsp70-Ssa1/2, Hsp40-Ydj1) did not change significantly after exposure. ROS levels and SOD and CAT activities rose after short-term exposure but not after long-term exposure.
Sanie-Jahromi F, Saadat M · 2017
Kim HS et al. · 2017
Researchers exposed Sprague-Dawley rats to a 915 MHz radiofrequency identification signal at a whole-body specific absorption rate of 2 W/kg for 8 hours per day, 5 days per week, for 2 weeks. The number of red blood cells and values of hemoglobin, hematocrit, and red blood cell indices were increased in the RFID-exposed group compared with the cage-control and sham-exposed groups. The number of white blood cells, including lymphocytes, was decreased in RFID-exposed rats, though T-cell counts and the CD4+/CD8+ ratio showed no statistically significant difference between sham-exposed and RFID-exposed groups. The researchers noted that these changes do not necessarily indicate that RFID exposure is harmful, as they were within the normal physiological response range.
Ibitayo AO et al. · 2017
Researchers divided young male rats into four groups, with three groups exposed to 2.5 Ghz radiation for 30, 45, or 60 consecutive days. DNA damage was detected using agarose gel electrophoresis, and histomorphometry showed perivascular congestion and tissue damage.
A method of simulating thermal mapping of positioning laptop on laps of an adult man was developed et al. · 2017
Suzuki S et al. · 2017
The purpose of this study was to evaluate the effects of 3rd-generation (3G) cellular phone radiofrequency-electromagnetic wave (RF-EMW) exposure on fertilization and embryogenesis in mice. Oocytes and spermatozoa were exposed to 1.95 GHz RF-EMWs at 2 mW/g for 60 minutes or sham exposure. After RF-EMW exposure, in vitro fertilization and intracytoplasmic sperm injection were performed. Groups compared were both exposed, both non-exposed, one exposed, and the other non-exposed. Fertilization, embryogenesis, and blastocyst formation rates did not change significantly across the four groups.
Das S, Chakraborty S, Mahanta B. · 2017
Researchers conducted a cross-sectional study among medical students who had used mobile phones for the past 5 years. They assessed the effect of mobile phones on pure tone audiometry thresholds in the exposed ear and the non-exposed ear. The study found a significant difference in average air conduction and bone conduction hearing thresholds between the exposed and non-exposed ears. A significant rise in both air and bone conduction thresholds at individual frequencies between the exposed and non-exposed ears was also noted.
Unknown authors · 2017
Pregnant mice were exposed continuously to 7.5 kHz magnetic fields at 12 and 120 μT from mating until weaning. The 12 μT group performed better on the Rotarod task and the 120 μT group swam more slowly in the Morris swim task, but these findings were considered likely due to chance. Histopathological analysis revealed no effect on astroglial reactivity or hippocampal neurogenesis.
Bourdineaud JP et al. · 2017
Researchers exposed Eisenia fetida earthworms to electromagnetic fields at 900 MHz and field levels ranging from 10 to 120 V m-1 for a period of two hours. All exposure treatments induced significant DNA modifications, and the number of probe hybridisation sites showed a significant two-fold decrease even after 24 hours of recovery. Genes involved in general stress, oxidative stress, and immune defence were up-regulated after exposure, and Western blots confirmed an increased quantity of HSP70 and MTCO1 proteins.
Samiee F, Samiee K. · 2017
Researchers examined how extremely low frequency electromagnetic field (ELF-EMF) exposure at 50 Hz affected brain tissue in Cyprinus carpio, a common carp species from the Caspian Sea. A total of 200 healthy fish were divided into a sham-exposed group and an experimental group exposed to five different magnetic field intensities (0.1, 1, 3, 5, and 7 mT) at two different exposure times (0.5 and 1 h). Exposure caused severe histopathological changes in the brain at field intensities of 3 mT or higher, leading to brain necrosis, with field intensity and duration of exposure identified as key parameters in causing lesions.
Bourdineaud JP et al. · 2017
Scientists exposed earthworms to cell phone radiation (900 MHz) for two hours at levels far below safety limits. The worms showed DNA damage and stress responses that lasted over 24 hours after exposure ended, suggesting even brief, low-level mobile phone frequencies cause lasting biological harm.
Zhang KY et al. · 2017
Researchers exposed mouse spermatocyte-derived GC-1 cells to a 1950 MHz RF field at 3 W/kg SAR for 24 hours with or without 6 Gy X-ray irradiation. RF exposure alone did not change cell proliferation or apoptosis levels. When combined with X-ray, RF exposure significantly decreased proliferation and increased apoptotic rate compared to X-ray alone. The combined exposure also significantly decreased Bcl-2 protein expression and increased Bax protein expression.
Kulaber A, Kerimoğlu G, Ersöz Ş, Çolakoğlu S, Odacı E. · 2017
Researchers exposed male rats to 900 MHz EMF for 1 h/day on postnatal days 22–59. Malondialdehyde levels increased in the EMF group compared to the other groups. Extravascular erythrocytes were observed in the medullary and corticomedullary regions of the thymus in exposed rats.
Conclusion The study was an attempt to draw attention towards the adverse effects of non-ionizing electromagnetic radiations (NI-EMR) in the frequency that is used widely in the field of telecommunication et al. · 2017
The study used computer simulations to investigate laptop thermal effects from electromagnetic fields and thermal sources simultaneously. Simulations provided steady-state temperature, SAR distribution, and heat flux beneath the laptop. The laptop in high performance mode generated a peak heat flux of 420 W/m², and combined with 1 W antenna radiation increased lap skin, scrotum, and testis temperatures by 5.6, 2.1, and 1.4 °C respectively. The antenna radiation alone produced peak SAR values of 0.37×10⁻³ W/kg at 2.4 GHz and 0.13×10⁻¹ W/kg at 5 GHz, considered negligible relative to safety standards.
Lippi G et al. · 2017
Researchers collected two sequential citrated blood samples from 16 healthy volunteers and exposed one sample to a smartphone call for 30 minutes at 900 MHz. Exposure significantly prolonged collagen-epinephrine aggregation by a median of 10% and increased mean platelet volume by a median of 5%. Collagen-adenosine diphosphate aggregation and platelet count did not change.
Lewis RC et al. · 2017
Researchers numerically compared dosimetric results among adult, child, and infant models for an EAS system operating at 125 kHz and 13.56 MHz. Postures insignificantly influenced dosimetric results when the cross-sectional area under exposure was similar. Although safety limits were unlikely to be exceeded, infants had higher SAR values for brain and central nervous system tissues than adults, by 1.5 times at 125 kHz and 112 times at 13.56 MHz. The infant's specific anatomy, such as a non-proportionally large head and high fat content, did not induce higher SAR values. The numerical models developed, including stroller and postured infant models, could be freely used for nonprofit academic research.
Unknown authors · 2017
The study examined how low-frequency magnetic fields affect morphine tolerance in rats. Rats received morphine 10 mg/kg daily for eight days and were exposed to magnetic fields at 50 Hz (1, 50, 100 µT) before, immediately, or 30 minutes after each injection, and also to 0.5, 6, 12, and 30 Hz at 100 µT before injection. Exposure to 50 Hz at 1 µT and 30 Hz at 100 µT immediately before injection, and 50 Hz at 100 µT after injection, prevented tolerance, whereas exposure to 50 Hz at 1, 50, and 100 µT 30 minutes after injection did not preserve analgesia.
Open access paper: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5585657/ -- Yorgancilar E et al. · 2017
Sixteen Wistar albino rats were divided into sham and exposure groups. The exposure group received 2.4 GHz RFR from a Wi-Fi generator for 24 h/day for one year at a distance of 50 cm. Distortion product otoacoustic emissions were measured at baseline, at 6 months, and at 12 months. At 6000 Hz, DPOAE values in the exposure group were lower than in the sham group and also lower at 12 months than at baseline and 6 months, while at 2000 Hz DPOAE values at 6 and 12 months were higher than baseline.