Rate Effects in Isolated Turtle Hearts Induced by Microwave Irradiation
Charles E. Tinney, James L. Lords, Carl H. Durney · 1976
Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.
Showing 430 studies in Cardiovascular
Charles E. Tinney, James L. Lords, Carl H. Durney · 1976
Terry O. Steiner · 1975
The system provides continuous monitoring of pacemaker output and simulates normal cardiac activity at the pacemaker leads using fiber optics for electrical isolation. The monitor presents a resistive load of approximately 1000 ohms that drops to about 500 ohms when the LED fires during a pacemaker pulse. The entire system was successfully tested at 26.6 MHz and near RF emitters from 200 to 3000 MHz, and the simulator addition did not affect the pacemaker threshold.
Richard D. Phillips et al. · 1975
Larsen JP, Eriksen T · 1975
DETLEF ROHL et al. · 1975
Przemyslaw CZERSKI, Stanislaw SZMIGIELSKI · 1975
The review explains that microwave bioeffects data come from animal experiments, model studies, and epidemiological research on occupationally exposed persons. Animal experiments are divided into acute high dose and chronic low dose exposures, with high dose effects explained by non-uniform deep body heating. Chronic exposure effects, especially frequency and modulation dependent effects in the nervous and hematopoietic systems, cannot be explained by thermal considerations alone.
D. Melville, F. Paul, S. Roath · 1975
Approximately 70% of red cells were retained until the field was turned off, with no evidence of immediate cell destruction. Scanning electron microscopy revealed slight surface abnormalities on a small proportion of filtered cells.
A.S. HYDE, J.J. FRIEDMAN · 1975
P. E. Hamrick, J. G. Zinkl · 1975
Researchers exposed rabbit erythrocytes to 2450 and 3000 MHz microwave radiation at multiple intensities to test for changes in potassium efflux and osmotic resistance. No significant differences were found between exposed and control cells in potassium efflux, osmotic resistance, or hemoglobin efflux.
L. Birenbaum et al. · 1975
Nicholas P. DrSmyth et al. · 1974
Only 10 documented cases of EMI affecting pacemakers were found, and none were serious or fatal. The authors concluded that environmental EMI does not constitute an important clinical problem for pacemaker patients at this time.
V. M. Koldaev · 1974
Researchers exposed albino mice to acute microwave radiation at 62±5 milliwatt/cm² for 11 minutes and to chronic radiation at the same intensity for 20 days at 6 minutes daily. Survival increased one and a half fold with cordiamine treatment. No positive effect of ephedrine was revealed.
Przemysław CZERSKI · 1974
W. D. SKIDMORE, S. J. BAUM · 1974
Todorov, N., Draganov, Y. · 1974
Mitchell JC, Hurt WD, Walters WH · 1974
Donald R. Koerner, M.D. · 1974
R. V. RAJOTTE et al. · 1974
J. L. Lords, C. H. Durney, A. M. Borg, C. E. Tinney · 1974
Researchers exposed isolated turtle hearts submerged in Ringer's solution to continuous 960-MHz microwave irradiation while measuring heart rate and force of contraction. At a total input power of 100 mW, corresponding to an estimated 3.3 mW absorbed by the heart, the average heart rate decreased (bradycardia). The authors concluded that the bradycardia could not be explained by heating because raising the bath temperature increased heart rate. They hypothesized that microwave stimulation of nerve remnants in the heart caused the bradycardia.
A. A. Marino, T. J. Berger, R. O. Becker · 1974
I. S. Fedorova, et al · 1974
Volkova AP, Fukalova PP · 1974
In laboratory experiments, one group of outbred white rats was exposed to 14.88 MHz short waves at 2,250 V/m for one hour, a second group at 100 V/m for four hours, and a third group served as controls. Workers at a station where field intensities exceeded permissible limits showed two-fold lower phagocytic activity and four-fold higher mouth autoflora, while workers at stations within limits had values within normal ranges.
Hamid Dalili, John Adriani, Wei T. Wu, Monroe S. Samuels · 1973
Water bath warming to 97±1°F did not alter electrolyte or enzyme levels in banked blood. The microwave warmer caused hemolysis in 35% to 40% of blood samples warmed.
David B. Geselowitz · 1973
Davis JA · 1973