СОСТОЯНИЕ ЗДОРОВЬЯ ОБСЛУЖИВАЮЩИХ ГЕНЕРАТОРЫ ВЫСОКОЙ (ВЧ), УЛЬТРАВЫСОКОЙ (УВЧ) И СВЕРХВЫСОКОЙ (СВЧ) ЧАСТОТЫ В ФИЗИОТЕРАПЕВТИЧЕСКИХ КАБИНЕТАХ
Е. И. Смурова, Г. З. Гослант, И. Л. Якуб, С. А. Троицкая · 1966
Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.
Showing 357 studies in Symptoms & Sensitivity
Е. И. Смурова, Г. З. Гослант, И. Л. Якуб, С. А. Троицкая · 1966
Goncharova NN, Karamyshev VB, Maksimenko NV · 1966
Hornowski J, Marks E, Chmurko E, Panneri L, Wojskow · 1966
E. A. Drogichina et al. · 1966
Heinrich Dinkloh · 1966
E. A. Drogichina et al. · 1966
Lysina, G. G. · 1965
The exposed workers were grouped by exposure duration and by intensity relative to the permissible threshold. Erythrocyte content did not change significantly (p > 0.5) in the exposed group. Reticulocytes were increased in 14% of exposed subjects compared with 8.7% of controls. Basophile granules increased quantitatively and erythrocyte sedimentation was slowed in 30% of cases.
Loshak A Y · 1965
Tiagin NV · 1965
Sol M. Michaelson et al. · 1965
Researchers exposed adult mongrel dogs to pulsed microwaves at 1285 Mc/sec and 2800 Mc/sec at various power densities. Body weight loss correlated directly with power density and was similar at both frequencies at comparable intensities. At 1285 Mc/sec, rectal temperature rose markedly at 100 mW/cm² during the first week then moderated, with progressive lowering of pre-exposure temperatures suggesting adaptation.
M. A. Sobakin · 1965
H. C. Sommer, H. E. von Gierke · 1964
William Talver Harvey, James Page Hamilton · 1964
Sagov S · 1964
L. Minecki · 1964
Allan H. Frey · 1963
Bielicki Z, Baranski S, Czerski P, Haduch S · 1963
Weiske, Clarence W. · 1963
Frey AH · 1963
Researchers measured alternating electric fields at a VLF transmitter site operating at 14.7 kc with 1100 kw radiated power. At the tower top center the field was 30,000 volts per meter and tingling occurred on bare metal and sometimes on painted metal. At the ladder top the field reached 989,000 volts per meter, producing strong shocks comparable to a 115 volts ac line and causing reflex withdrawal without muscle freezing.
Palladin AM · 1962
Alfonso Mungo · 1962
Frey AH · 1961
David E. Goldman · 1960
E. HENDLER, J. D. HARDY · 1960
Researchers exposed the forehead area of seven subjects to controlled heating while measuring skin temperature radiometrically. Temperature sensation reports correlated best with the rate of change of skin temperature. Warmth threshold occurred at a skin temperature rise rate of 0.001°C/second and cool threshold at a fall rate of 0.005° °C/second. Microwave irradiation at about 17 mW/cm² produced a linear skin temperature increase of 0.037°C/second for the first 30 seconds. Warmth sensation persisted after microwave exposure ended, which the authors attributed to slowly dissipated heat retained in the tissues.
Cazzamalli, Ferdinando · 1960