6,486 Studies Reviewed. 85.2% of Original Studies Found Biological Effects. The Evidence is Clear.

EMF Research Studies

Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.

Filter Studies

Clear all filters

Showing 2,816 studies in Whole Body / General

EFFECTS OF LOW POWER MICROWAVES ON THE LOCAL CEREBRAL BLOOD FLOW OF CONSCIOUS RATS

Unknown authors

Researchers measured local cerebral blood flow in multiple brain regions of conscious rats using a radioactive iodoantipyrine technique. Rats were exposed for 30 minutes to pulsed microwaves at 1 mW/cm² or 15 mW/cm² average power density, or sham exposure. Both exposure levels increased blood flow by 10 to 144 percent in 16 of 20 regions, with the largest significant increases in the pineal, hypothalamus, and temporal cortex at 1 mW/cm² and in the pineal, temporal cortex, inferior colliculus, and medial geniculate at 15 mW/cm².

TENSOR INTEGRAL EQUATION METHOD COMBINED WITH ITERATION TECHNIQUE FOR QUANTIFYING INDUCED EM FIELDS IN BIOLOGICAL SYSTEMS

Unknown authors

Researchers developed a computational scheme that combines an iteration process with the tensor integral equation method to quantify induced electric fields in electrically large bodies. In a test on a muscle layer irradiated by a 1 GHz plane wave, the 8-cell model with iteration produced results comparable to a 64-cell model at a lower computation cost.

Differential Heating of the Cortex, Hypothalamus and Rectum in Three Species by 2450-MHz Microwaves

Unknown authors

Animals were irradiated at 30 to 40 mW/g until rectal temperature reached 42.5 to 43.0 °C, then temperatures were recorded for over three hours. At baseline, cortical and hypothalamic temperatures were significantly lower than rectal temperatures in all three species. After heating, cortical temperature fleetingly exceeded rectal temperature in all species, while hypothalamic temperature exceeded rectal temperature only in rabbits. Brain temperatures fell rapidly in the first minute after exposure while rectal temperature declined much more slowly.

CHARACTERISTICS AND MEASUREMENTS OF MICROWAVE AND RADIOFREQUENCY RADIATION

Bureau of Radiological Health, Food and Drug Administration

Microwaves and RF fields are almost totally reflected from metals, transmitted through plastics, ceramics, paper, or glass, and absorbed by most biological materials, particularly those with high water content. The document explains near-field and far-field regions, noting that the near field dominates when the distance is much smaller than the wavelength and that the far field begins where the ratio of electric to magnetic field approaches 377 ohms. It specifies measurement techniques for frequencies from 1 MHz to 100 GHz and distinguishes emission standards from exposure standards.

Whole Body / General
Not an original health-effects study

PRELIMINARY RESULTS OF OUTPUT PERFORMANCE TESTS ON TENS DEVICES

D.M. Witters, S.M. Hinkley, A.R. Lapp

Researchers measured electrical output signals of several commercially available TENS devices using a digital waveform signal recorder across the ANSI/AAMI standard loading circuit. Most devices generated asymmetrical biphasic waves, while some produced monophasic or polyphasic pulses. Some devices, such as the Maxima, showed fairly accurate pulse rate control settings with nearly linear actual pulse rate across the control range. The study concluded a wide variety of designs and performance exists, and further research is needed to correlate parameters with safety and effectiveness.

PROBLEMS OF OCCUPATIONAL HYGIENE IN HANDLING ULTRASHORT WAVE RADIO TRANSMITTERS USED IN TV AND BROADCASTING

N. N. Goncharova, V. B. Karamyshev, N. V. Maksimenko

The paper examines occupational hygiene and effects of ultrashort wave electromagnetic fields on TV and radio station employees. Physiological investigations at workplaces found that operators servicing ultrashort wave transmitters exhibit functional changes in cardiovascular and central nervous systems during the day. The high-frequency electromagnetic field of considerable intensity was identified as an especially unfavorable factor. Protective and prophylactic measures are needed to improve work conditions.

CardiovascularNo Effects Found

EFFECTS OF MICROWAVE IRRADIATION IN VIVO ON RABBIT BLOOD SERUM

Lewis C. Gershman

Researchers exposed rabbits to microwave radiation at 5.85 GHz pulsed or 2.45 GHz continuous wave at 15 milliwatts/cm² for one hour daily over ten days. The previously reported decrease in albumin/globulin ratio was not observed. The authors concluded that microwave irradiation under these conditions had no significant effect on the animals' physiologic processes.

Browse by Health Effect