Recommended Consultants for External Review of the Radiofrequency (RF)/Microwave Radiation Criteria Document
Criteria Manager, RF/Microwave Radiation Criteria Document · 1979
Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.
Showing 1,318 studies matching "radiofrequency"
Criteria Manager, RF/Microwave Radiation Criteria Document · 1979
Unknown authors · 1979
Unknown authors · 1979
R.A. Tell, F. Harlen · 1979
The authors reviewed selected biological effects and dosimetric data to develop radiofrequency safety standards based on thermogenic properties of electromagnetic fields. The 10 mW/cm² limit appears adequate for frequencies above 1 GHz but may be too high for lower frequencies due to body resonances causing increased energy deposition and local temperature rises. They noted that energy absorption in small laboratory animals can be up to 30 times greater than in humans at the same field strength. The current averaging period of 0.1 hours is considered unjustifiably short.
Stan Neuder · 1979
Helen C. Chase · 1979
Robert P. Liburdy · 1979
Researchers exposed mice to whole-body radiofrequency radiation at 26 MHz that raised core temperature by 2°C over 15 minutes, inducing transient lymphopenia and increasing splenic T- and B-lymphocytes. Repeated RFR exposures sustained lymphopenia and further elevated splenic T- and B-lymphocyte levels. Chronic RFR exposure decreased thymic weight, thymic and splenic cell density, and suppressed delayed-type hypersensitivity. Warm air exposure increased only splenic B-lymphocytes and did not change delayed hypersensitivity, while RFR exposure raised plasma corticoid levels severalfold. A synthetic glucocorticoid reproduced the lymphopenia, splenic T- and B-lymphocyte increases, and thymic involution observed with RFR.
Clinton Cox, Betsy Egan, Bill Murray, Bob Herrick · 1979
On November 29, 1978, NIOSH conducted a walk-through survey of the RF sealing area at Standard Plastic Products in South Plainfield, New Jersey. The purpose was to identify workers for a study on health effects from occupational radio frequency radiation exposure. Electric and magnetic fields from the heat sealers were measured and corrected for duty cycle. All three sealers produced electric fields greater than 1000 V/M, exceeding the ANSI guideline of 200 V/M by at least five times. A cohort of 15 workers, mostly elderly women, was identified and could be used in a study if combined with similar cohorts from other plants.
Unknown authors · 1979
Unknown authors · 1978
Unknown authors · 1978
Instruments should read average power density, mean squared electric field strength, mean squared magnetic field strength, or energy density. Calibration methods include free-space standard field, guided wave methods, and standard probe method.
M. H. Repacholi · 1978
M. Repacholi · 1978
Descriptions are given on the physical characteristics, biophysical principles, and biological effects of exposure to these radiations. Public and occupational health implications and protective measures against the hazards of exposure are also described. Existing standards for general public and occupational exposure have been tabulated and described to inform the reader about presently accepted maximum permitted exposure levels.
Science Information Services Department · 1978
Rats exposed to pulsed radiofrequency or microwave frequencies for up to three hours a day over 0.5 to 6.0 months showed chemical and cellular blood changes, reduced cardiac, hepatic, and neural metabolism, hepatic histologic changes, and severe testicular damage. Mice exposed to 9 GHz for a few minutes a day for 59 weeks developed monocytic leukosis and myeloid leukemia three times as often as controls. Human studies included a Russian report that cardiovascular patients chronically exposed to microwave radiation did not improve after changing jobs, a Finnish study correlating a radar site with increased fatal heart attacks, and a study of 140 radio and television operators with at least 10 years exposure showing elevated alpha-globulin and total serum protein.
H. Bassen, J. Sing · 1978
When a hazard is detected, the controller activates alarms and shuts off the high-power source through redundant relays. The system has been tested with multiple high-power generators and a commercial version is in use.
G. I. Rowlandson, P. W. Barber · 1978
Richard F. Boggs, Zorach R. Glaser · 1978
John R. Frazier, Thomas R. Ohlhaber, Paul S. Ruggera · 1978
Unknown authors · 1978
Unknown authors · 1978
It applies to military and civilian personnel at Air Force facilities worldwide and addresses protection of nonoccupationally exposed personnel from Air Force-owned sources. Warning signs are required where access to power density levels exceeding the PEL is probable.
Unknown authors · 1978
Richard A. Tell · 1978
The report analyzes existing radiofrequency and microwave absorption data to examine frequency-dependent tissue heating and determine exposure field intensities linked to thermal loading on the whole body and specific tissues in adults and infants. A baseline absorption factor of 1 W/kg, equivalent to the adult basal metabolic rate averaged over total body mass, is used for comparison. In the 10 MHz to 1000 MHz range, absorption can produce whole-body thermal loads several times the basal metabolic rate at the present U.S. safety standard.
Quirino Balzano, Oscar Garay, Frances R. Steel · 1978
Researchers built two phantom models to study heating of simulated human tissue from VHF portable radio antennas. Temperature measurements showed penetrating power densities in the tissue were substantially lower than expected from an incident plane wave with the same electric field intensity. In the head phantom, a 6-W radio held 0.2 inches from the mouth caused less than 0.1°C temperature rise in one minute. The maximum power density penetrating the dummy was less than 1 mW/cm² at the middle forehead, and no detectable temperature increase occurred near the eyes.
Unknown authors · 1978
The criteria document was scheduled for completion by August 1979. Preparation involved NIOSH research, literature review, stakeholder communication, plant visits, and expert review. Recommendations were based on critical evaluation of biological effects and epidemiological data, plus instrumentation, engineering controls, work practices, and medical monitoring. Over 300 letters were sent to manufacturers, users, trade associations, and organized labor, yielding approximately 70 responses.
R. A. Tell, F. Harlan · 1978