6,486 Studies Reviewed. 85.2% of Original Studies Found Biological Effects. The Evidence is Clear.

EMF Research Studies

Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.

Filter Studies

Showing all 6,486 studies

Physiological Effects of Electromagnetic Fields in the ELF Region II. A Review

W. Ludwig, M. A. Persinger, K.-P. Ossenkopp · 1973

Researchers exposed rats prenatally to a 0.5 Hz, 0.5—30 gauss rotating magnetic field and observed behavioral and physiological changes. Prenatally exposed rats showed less ambulatory behavior and greater defecation in an open field test. In a free-operant avoidance task, exposed rats pressed the lever significantly less but received similar numbers of shocks as controls. Exposed rats also had significantly increased relative thyroid and testicle weights, with no changes in blood sugar or eosinophil counts.

Microwave Dielectric Properties of Grain and Seed

Stuart O. Nelson · 1973

The study measured the dielectric constant and loss factor of bulk wheat samples at 1, 2.44, and 5.54 GHz. For hard red winter wheat, both properties increased almost linearly with moisture content from 6% to 21%. The dielectric constant decreased with frequency, more at higher moisture, while the loss factor showed little frequency dependence but tended to increase at high moisture.

Accuracy of Cardiac Auscultation by Microwave

Raymond L. H. Murphy et al. · 1973

Fifty subjects, including twenty-seven patients with known heart murmurs and the remainder normal volunteers, were examined both directly and via a microwave telestethoscope by an observer 2.7 miles away who was blinded to their status. All murmurs of grade 2/6 or louder were accurately described, while two of the 32 grade 1/6 murmurs were not heard. Overall findings matched in 98 percent of cases, with 19 of 24 systolic murmurs graded identically and five differing by one grade.

Depression of phagocytosis: a non-thermal effect of microwave radiation as a potential hazard to health

C. P. MAYERS, J. A. HABESHAW · 1973

Researchers exposed mouse macrophage monolayers perfused with human red blood cells to 2450 MHz microwave radiation at 50 mW/cm² for 30 minutes while maintaining temperature at 37°C. The phagocytic index fell to 6.3 ± 2.5 per cent in irradiated cultures compared with 20.2 ± 5.8 per cent in unirradiated controls, a statistically significant difference (P < 0.025). Phagocytic activity returned to normal after radiation was stopped, and no morphological changes were observed in the macrophages.

SOME BIOLOGICAL EFFECTS OF MICROWAVE IRRADIATION IN THE RAT

T. Daryl Hawkins et al. · 1973

In the lethality study, one hundred and seventy-four male Wistar rats were exposed to 3000 MHz microwave radiation, and the lethal energy density (LD50) increased with longer exposure durations. The lethal power density required for a lethal effect decreased as exposure duration increased. At each frequency, higher power levels resulted in shorter times to work stoppage. At all power levels which resulted in a complete cessation of performance, 1700 MHz produced the shortest stoppage times, while both higher and lower frequencies had progressively less influence.

ELECTROMAGNETIC POWER DEPOSITION IN MAN EXPOSED TO HIGH-FREQUENCY FIELDS AND THE ASSOCIATED THERMAL AND PHYSIOLOGICAL CONSEQUENCES

Arthur W. Guy et al. · 1973

Researchers used a spherical mathematical model to simulate heat transfer and thermoregulation in a nude man resting at 28° C. and 50% RH, exposed to 100 watts of deposited power corresponding to 590 mw./cm.2 at 20 MHz. The study also calculated that incident power densities of 3540 and 900 mw./cm. at 20 MHz would produce a heat stress index of 100 for a man at rest and at work, respectively, in an environment of 25°C., 50% RH, and 15 mb.

Induction of Germination of Impermeable Cottonseed by Electrical Treatment

R. B. Stone et al. · 1973

Glow-discharge treatments at 60 Hz, 15 kHz, and 17.5 kHz for 3 minutes in an evacuated tube raised germination from below 10% to 60–90% in laboratory tests. RF treatments at 1.3–3.1 kV/cm also significantly increased germination, but generally not as much as glow-discharge. In a field test with saw-ginned seed, RF treatment raised emergence from 50% to 76%, while glow-discharge did not significantly increase emergence.

Effects of active magnetic fields on permanently implanted triggered pacemakers

Nicholas P. D. Smyth et al. · 1973

Fifty-two patients with triggered ventricular, atrial, A-V synchronous, and A-V sequential pacemakers were exposed to magnetic fields generated by fixed and portable weapons detectors ranging from 100 Hz to 450 kHz at 0.5 to 1.35 gauss. No standard ventricular pacemaker, unipolar or bipolar, was affected by any of the weapons detectors. Of the eight patients with sensitive atrial pacemakers, one showed a single-beat rate increase that was not reproducible on repeat testing. In the two sensitive A-V groups, a brief rate change occurred in all three patients in each group, and any changes resolved immediately after leaving the magnetic field. No pacemaker stopped functioning, post-test ECGs showed no persistent rate changes, and no patient reported symptoms during exposure.

LOW-LEVEL MICROWAVE INTERACTION WITH ISOLATED MAMMALIAN HEARTS

R.G. Olson, C.H. Durney, J.L. Lords, C.C. Johnson · 1973

Researchers used isolated rat hearts back-perfused with oxygenated Ringer's solution and exposed them to microwave radiation in a stripline configuration inside a Faraday shield. Hearts were stabilized for 30 minutes then irradiated for 30 minutes at an absorbed power of 1.5 to 2.5 mW/cm³, which was determined using a liquid crystal optical fiber temperature probe. Exposure caused pronounced bradycardia, with heart rates decreasing 15 to 40 percent below baseline or temporary cessations of 5 to 12 seconds, and the effect reversed within 2 to 8 minutes during continued irradiation.

Browse by Health Effect