CLINICAL ASPECTS OF THE EFFECT OF METRIC RANGE ELECTROMAGNETIC FIELDS
A. I. Kleyner et al. · 1975
Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.
Showing 2,816 studies in Whole Body / General
A. I. Kleyner et al. · 1975
C. R. Jenkins, D. L. Durgin · 1975
D J Blundell · 1975
The paper describes the UK primary noise standard in the 3.75–4.25 GHz band, emphasizing simplicity in cryogenic noise standards and noting difficulties in calibrating previous designs. A model in waveguide size WGI1A (WR-229) is described and analysed in detail, featuring a termination with a kapton polyimide window, a copper gasket, and a conical silicon carbide resistive element, and an unplated steel transition section. The standard has operated successfully for two years, including an international intercomparison with Japan, with output noise temperature variation typically 5 mK due to gas flow changes.
Stewart J. Allen et al. · 1975
Researchers calculated and measured radiofrequency power absorption from 10 to 50 MHz in prolate spheroid phantoms and live monkeys. Monkey orientation affected absorption, with monkeys on their sides absorbing more power than on their backs for cross and magnetic polarization.
L. E. DAVIS, SUSAN SHURIN, R. T. JOHNSON · 1975
Researchers cultured embryonic chick tibiae in vitro and exposed them to either a static or a pulsed electric field. Histological examination and macroscopic photographs showed no differences in growth patterns between test and control bones.
Unknown authors · 1975
G. N. Catravas · 1975
Chung-Kwang Chou · 1975
John M. Osepchuk · 1975
DETLEF ROHL et al. · 1975
Unknown authors · 1975
Om P. Gandhi · 1975
D.W. Peak, D.L. Conover, W.A. Herman, R.E. Shuping · 1975
Gabriel G. Nahas et al. · 1975
Michaelson, 1975 · 1975
Watson et al. · 1975
Watson et al. found that the growth rate of embryonic chick tibiae in vitro was enhanced by a pulsed electric field of 1,000 V cm but not by a static field. The authors suggest that the lack of enhancement in a static field is due to the ability of the cultures to sustain a field. They explain that during the 9-day growth period in a steady field there is no field within the bone, no charge movement, and thus no bioelectric command signal except at the instants when the field is switched on or off. They derive a relaxation time constant of about 10 seconds for the tissue, indicating that in a steady field there is no transducer mechanism available.
Carl H. Durney, Curtis C. Johnson, Habib Massoudi · 1975
Medical Instrument Research Associates, Inc. · 1975
Unknown authors · 1975
Przemyslaw CZERSKI, Stanislaw SZMIGIELSKI · 1975
The review explains that microwave bioeffects data come from animal experiments, model studies, and epidemiological research on occupationally exposed persons. Animal experiments are divided into acute high dose and chronic low dose exposures, with high dose effects explained by non-uniform deep body heating. Chronic exposure effects, especially frequency and modulation dependent effects in the nervous and hematopoietic systems, cannot be explained by thermal considerations alone.
Smith and Powstenko · 1975
D. Melville, F. Paul, S. Roath · 1975
Approximately 70% of red cells were retained until the field was turned off, with no evidence of immediate cell destruction. Scanning electron microscopy revealed slight surface abnormalities on a small proportion of filtered cells.
Sol M. Michaelson, Sandra W. Magin · 1975
A.S. HYDE, J.J. FRIEDMAN · 1975
Unknown authors · 1975