Heat as Cancer Therapy
Bull JM, Chretien PB · 1976
Browse 6,486 peer-reviewed studies on electromagnetic field health effects from 4 research libraries.
Showing all 6,486 studies
Bull JM, Chretien PB · 1976
Elmqvist H · 1976
The paper describes interference mechanisms, the most common sources of external electromagnetic interference, and their influence on different types of pacemakers. It identifies three ways external electromagnetic interference can influence pacemaker function. Remote sources include microwave ovens, radar installations, and radio-transmitters, while direct contact sources include defibrillation, diathermy, short-wave treatment equipment, and household appliances with poor insulation. A survey of over 2200 patients found only 10 cases of interference with no serious consequences. Modern pacemakers use an interference filter that discriminates signals by repetition rate and a metal encapsulation that reduces microwave effects.
McRee DI · 1976
James C. Lin · 1976
The study compares radiation pressure, restrictive force, and rapid thermal expansion as possible transduction mechanisms for the microwave auditory effect. At a peak absorbed power density of 2400 watt/m² for 2450 MHz radiation, the computed maximum stress is approximately 0.02 Newtons/m², which is above the bone-conduction hearing threshold.
Lin JC, Wu C-L · 1976
Ernest N. Albert · 1976
K. Gheleta · 1976
Roberts Rugh, Henry Ho, Mary McManaway · 1976
Pacific Measurements Inc. · 1976
Model 1036 measures from -40 dBm to +10 dBm in a single range while Model 1037 measures from -30 dBm to +20 dBm. The instruments achieve rated accuracy of +0.02 dB on the upper 30 dB and +0.04 dB on the lower 20 dB of the power range. A self-check feature uses a front-panel calibrator providing 10 milliwatts accurate within +0.06 dB at 30 MHz. The detectors are protected against overloads up to 10 times full-scale rating and are field-repairable.
David E. Janes · 1976
In March 1975 the Environmental Protection Agency requested data on health and environmental effects of extremely high voltage transmission lines. By March 1976 the agency had received over 50 responses comprising more than 6,000 pages of material. This report lists each respondent with a brief description of their submission and provides an alphabetical bibliography of the technical materials received. The submitted technical material consists mostly of published articles along with some technical memorandums and internal reports. Bibliographies supplied by respondents have not yet been compiled and readers are directed to the original submissions for those references.
Stephen D. Smith · 1976
James L. Mason, Neilson A. M. MacKay · 1976
Vernon L. Newhouse, Phillip J. Bendick, L. William Varner · 1976
The study derived a mathematical relation between the transmitted spectral density and the output spectral density for broad-bandwidth random-signal Doppler flow measurement systems operating under transit-time-limited conditions. The authors showed that random or pseudorandom Doppler systems give the same output spectrum as pulsed RF Doppler systems provided the transmitted spectral density envelopes match.
Claire A. Van Ummersen, Frances C. Cogan · 1976
Charles E. Tinney, James L. Lords, Carl H. Durney · 1976
Roberts Rugh · 1976
Researchers exposed 114 male and female mice of three distinct ages to 2450 MHz microwave radiation at 75 watts forward power until death. Time to death increased with age for both sexes, but the mean absorbed dose at death did not differ significantly with age or weight within the same sex.
J. Eugene Robinson, Duncan McCulloch, Edgar A. Edelsack · 1976
Researchers exposed mammary tumors on mice to 2450 MHz microwaves at up to 200 watts in a free-field setup. Microwave heating alone from room temperature was marginal and produced unacceptably high thermal non-uniformities. Adding warm air to preheat tumors to body core temperature allowed hyperthermic temperatures of 40°C and 43°C with only 30 watts of microwave power. However, the maximum temperature deviation within tumors remained about 1.5°C, exceeding the desired uniformity of less than 0.25°C.
John C.H. Wang, Jack M. Linthicum · 1976
Frank M. Greene · 1976
James W. Frazer et al. · 1976
At 1000 mW/cm², rectal temperature rose from 38.1°C to 39.4°C in the first half hour and then fell to 38.8°C, while skin temperature rose to 38.6°C and then fell to 37.2°C. At 750 mW/cm², skin temperature increased 1.4°C then declined 1.5°C, and rectal temperature increased 0.4°C to an equilibrium of about 37.8°C. Continuous 6-hour exposure at 750 mW/cm² raised rectal temperature by 1.7°C and skin temperature by 2.8°C.
Morris E. Brodwin, Allen Taflove, John E. Matz · 1976
Arthur W. Guy, Michael D. Webb, Carrol C. Sorensen · 1976
Researchers used thermographic measurements on scale models of humans in a VHF resonant cavity to determine power absorption characteristics for full-scale humans exposed to high-frequency electromagnetic fields. Peak power absorption densities of 5.63 W/kg were found for a human exposed to 10 mW/cm² at 31 MHz. Absorption decreased as the square of the frequency for frequencies below 31 MHz.
Peter A. Neukomm · 1976
Most telemetry equipment operates between 10 and 1000 MHz with radiated power from a few microwatts to approximately 2 W. Hot spots in animal brains show heating potential 10 to 15 times higher than predicted by the RAC method.
James H. Merritt, Richard H. Hartzell, James W. Frazer · 1976
Unknown authors · 1976
The review assessed human vulnerability, protection materials, and methods for military operations, using sources up to October 1975. It examined biological effects of radiofrequency and microwave radiation up to 300,000 megahertz, including both thermal and nonthermal effects. The review noted that Communist research relied heavily on animal and in vitro studies of systems such as blood, cardiovascular, and nervous systems, and that Communist exposure standards were more stringent than Western standards.