Janać B et al. · 2012
Researchers exposed young and older gerbils to power-line frequency magnetic fields for seven days. Both age groups showed significant behavioral changes, with younger animals becoming more active. The effects persisted three days after exposure ended, indicating potential lasting impacts on brain function.
Unknown authors · 2012
Researchers examined nocturnal profiles of blood parameters including electrolytes, nonprotein nitrogenous compounds, and glucose in 15 men exposed chronically to 50-Hz magnetic fields for 1 to 20 years. The exposed group had weekly geometric mean exposures ranging from 0.1 to 2.6 μT. Results were compared to 15 unexposed men of similar age with exposures ranging from 0.004 to 0.092 μT. Exposed men showed significant changes in serum sodium, chloride, phosphorus, and glucose for exposures greater than 0.3 μT. The authors concluded that long-term exposure above 0.3 μT could induce biological modifications of certain blood parameters, though clinical relevance needs further investigation.
Unknown authors · 2012
French researchers tracked 15 healthy men exposed to 50 Hz magnetic fields (power line frequency) for up to 20 years, comparing their blood chemistry to unexposed controls. Men with exposures above 0.3 microtesla showed significant changes in sodium, chloride, phosphorus, and glucose levels during nighttime blood sampling. The study suggests long-term power frequency exposure may alter basic blood chemistry, though the health significance remains unclear.
Vannoni D et al. · 2012
Researchers cultured isolated human osteoarthritic chondrocytes in vitro, some stimulated with IL-1beta or IGF-1 to mimic osteoarthritis imbalance. The cells were exposed to extremely low frequency (100 Hz) electromagnetic fields and to Therapeutic Application of Musically Modulated Electromagnetic Fields (TAMMEF) with variable frequencies, intensities, and waveforms. Using flow cytometry, they tested effects on chondrocyte metabolism. Exposure to both systems enhanced cell proliferation and did not generate reactive oxygen species, cause glutathione depletion, change mitochondrial transmembrane potential, or induce apoptosis.
Unknown authors · 2012
Researchers used an in vitro retrotransposition assay on human neuroblastoma BE(2) cells exposed for 48h to 1mT, 50Hz PMF or sham exposure. They also measured γ-H2AX foci as a marker of DNA DSB in both exposed and sham-exposed samples. PMF-exposed cells had a lower number of both retrotransposition events and DNA DSB compared with sham-exposed samples.
Korpinar MA, Kalkan MT, Tuncel H. · 2012
Researchers exposed rats to 50 Hz magnetic fields (the same frequency as household electrical wiring) for 21 days and measured their anxiety levels using standard behavioral tests. The exposed rats showed significantly higher anxiety and stress-related behaviors compared to unexposed rats, spending much less time in open, exposed areas of test mazes. This suggests that prolonged exposure to power-frequency magnetic fields may increase stress responses in the brain.
Akar A et al. · 2012
Researchers exposed adult male Wistar rats to 2.45 GHz microwave radiation at a SAR of 0.25 W/kg for 2 hours each day for 21 days and then measured corneal thickness using histological and stereological methods. Overall corneal thickness was 278.9 ± 54.5 μm in the control group and 272.4 ± 85.6 μm in the study group, with no statistically significant difference between groups. Anterior corneal epithelium thickness was 28.1 ± 4.9 μm in the control group and 31.7 ± 5.5 μm in the exposed group, a statistically significant difference. The researchers concluded that exposure to microwave radiation might cause alterations in the rat cornea.
Joseph W, Goeminne F, Vermeeren G, Verloock L, Martens L. · 2012
Researchers assessed electromagnetic exposure from 14 types of air traffic control systems for both workers and the general public. In total, 50 sites were investigated at 1,073 locations in the frequency range of 255 kHz to 24 GHz. Two system types, Non-Directional Beacons (up to 881.6 V m) and DVOR (up to 92.3 V m), exhibited levels requiring recommended minimum distances so that ICNIRP reference levels are not exceeded. When multiple radiofrequency sources were present together, the air traffic control source was found to dominate total exposure in its neighborhood.
Lahham A, Hammash A. · 2012
Researchers measured radiofrequency power density at 65 locations across the West Bank. The average power density from FM radio was 0.148 μW cm(-2), from TV broadcasting 0.007 μW cm(-2), and from mobile phone base stations 0.089 μW cm(-2). The average total exposure from all sources was 0.37 μW cm(-2). The maximum total exposure at any location was 3.86 μW cm(-2), with an exposure quotient of 0.02, indicating compliance with international guidelines. FM radio contributed about 62% of total exposure, mobile phone base stations 35%, and TV broadcasting 3%.
Sakhnini L, Al Ali H, Al Qassab N, Al Arab E, Kamal A. · 2012
Researchers investigated the possible effect of ELF-EMFs on motor performance in prenatal and neonatal exposed mice. Motor performance was evaluated using rotarod experiments after 5 days of subacute exposure. Prenatal exposed groups showed a pronounced deficit in learning abilities, but no pronounced effect was observed for the neonatal exposed group.
Vignola MB et al. · 2012
Researchers evaluated the effect of pulsed electromagnetic field (PEMF) therapy on inflammatory biomarkers associated with oxidative stress in rats with experimental myopathy. Myopathy was induced by injecting 50 μl of 1% carrageenan, and PEMF treatment was applied at 20 mT and 50 Hz for 30 min/day/rat. PEMF treatment was associated with decreased levels of fibrinogen, L-citrulline, NO, SOD, and carbonyl groups and significant muscle recovery.
Unknown authors · 2012
Researchers exposed female Fischer 344 and Lewis rats to a 50 Hz, 100 μT magnetic field for two weeks. Whole genome microarray analysis of mammary gland tissue revealed decreased α-amylase, carbonic anhydrase 6, and lactoperoxidase gene expression, and increased cystatin E/M expression in exposed F344 rats but not in Lewis rats.
Unknown authors · 2012
German researchers exposed two different strains of female rats to power line frequency magnetic fields (50 Hz at 100 microTesla) for two weeks and analyzed gene expression changes in breast tissue. They found that Fischer 344 rats showed significant alterations in multiple genes related to pH regulation and tumor suppression, while Lewis rats showed no changes, suggesting genetic factors determine susceptibility to EMF effects.
Unknown authors · 2012
Unknown authors · 2012
Chinese researchers exposed fresh human sperm samples to 50 Hz electromagnetic fields (the same frequency as power lines) at 0.4 mT strength for different time periods. They found that EMF exposure significantly reduced sperm motility after both 15 and 60 minutes, while sperm pH remained unchanged. This suggests that even brief exposure to power-line frequency EMFs can impair sperm function.
Unknown authors · 2012
The study used 66 NMRI pregnant females divided into treated and non-treated groups. The treated group was exposed to ELF-EMF at 50 Hz and 6×10-3 T. Embryos were collected by flushing the uterine horn and Fallopian tubes on day 3 of gestation. There was no significant difference in the mean number of blastocysts between treated and none treated groups. Exposed blastocysts had significantly fewer total cells, ICM cells, and TE cells, while the ICM/TE ratio increased.
Unknown authors · 2012
Researchers evaluated compensatory plasticity in the cockroach Periplaneta americana after sensory nerve injury and assessed the effect of electromagnetic field exposure (EMF, 50 Hz, 7 mT) and TGF-β. Ablation of the right cercus increased activity in the left presynaptic part of the sensory path.
Lu Y et al. · 2012
Researchers exposed Wistar rats to 2.45 GHz pulsed microwave irradiation at a power density of 1 mW/cm2 for 3 hours per day for up to 30 days. Microwave exposure induced spatial learning and memory impairments in rats, and reduced hippocampal glucose uptake in the absence or presence of insulin. Blood glucose and insulin levels were not affected, but spatial memory deficits were reversed by systemic glucose treatment.
Nazıroğlu M et al. · 2012
Researchers divided rats into four groups: a cage control, a sham control, a group exposed to 2.45 GHz electromagnetic radiation, and a group exposed to the same radiation while also receiving melatonin. The radiation-exposed groups received that exposure for 60 minutes per day for 30 days, after which brain cortex and dorsal root ganglion samples and EEG recordings were collected. Lipid peroxidation, cell viability, and cytosolic calcium values in dorsal root ganglion neurons were higher in the radiation-only group than in the control groups. The melatonin-plus-radiation group showed lower EEG spike numbers and higher brain cortex vitamin E concentration compared with the radiation-only group.
Yang XS, He GL, Hao YT, Xiao Y, Chen CH, Zhang GB, Yu ZP. · 2012
Researchers exposed adult male Sprague-Dawley rats to a 2.45 GHz electromagnetic field at a specific absorption rate of 6 W/kg, or to sham conditions, then examined gene and protein expression in the hippocampus. Of 2048 candidate genes examined, 23 were upregulated and 18 were downregulated. Two heat shock proteins, HSP27 and HSP70, stood out because their expression levels were increased in the rat hippocampus. The researchers concluded that their data provide direct evidence that exposure to electromagnetic fields elicits a stress response in the rat hippocampus.
Fournier NM, Mach QH, Whissell PD, Persinger MA. · 2012
Pregnant Wistar rats were continuously exposed to one of four intensities of a complex magnetic field throughout gestation. Exposure to weaker or stronger intensities of the same field pattern did not interfere with hippocampal development or fear behavior.
Korpinar MA, Kalkan MT, Tuncel H. · 2012
Anxiety and stress-related behavioral changes were investigated by elevated plus-maze and hole-board systems. In the elevated plus-maze, exposed rats spent proportionally less time on open arms than control rats (0.12±0.08 versus 0.34±0.18, p <0.01), while hole-board results showed no statistically significant differences between the two groups.
Rauš S, Selaković V, Radenović L, Prolić Z, Janać B. · 2012
Researchers studied how an extremely low frequency magnetic field affects motor behaviour in 3-month-old Mongolian gerbils that had undergone global cerebral ischemia. After a 10-minute blockage of both common carotid arteries, gerbils were continuously exposed to ELF-MF at 50 Hz and 0.5 mT for 7 days, and their behaviour was monitored on days 1, 2, 4, 7, and 14 after reperfusion. Ischemia alone caused significant increases in locomotion, stereotypy, and rotations, along with decreased immobility, up to day 4 after reperfusion compared to control gerbils. ELF-MF exposure inhibited ischemia-induced motor hyperactivity throughout the observation period, though significantly only in the first 2 days after reperfusion.
Rageh MM, El-Gebaly RH, El-Bialy NS. · 2012
Researchers exposed newborn rats continuously to a 50 Hz, 0.5 mT extremely low-frequency magnetic field for 30 days, starting when the rats were 10 days old. DNA damage in brain cells, measured by comet assay, was significantly higher in the exposed group. Exposure was associated with a significant four-fold increase in micronucleus induction and about a three-fold increase in mitotic index in bone marrow cells. Exposed rats also showed significantly higher levels of MDA and SOD, while ELF-MF failed to alter the activity of GSH.
Tasset I et al. · 2012
Researchers investigated the neuroprotective effects of extremely low-frequency electromagnetic fields (ELFEF) in a rat model of Huntington's disease induced by 3-nitropropionic acid (3NP). Rats were given 3NP over four consecutive days at 20 mg/kg body weight, and ELFEF at 60 Hz and 0.7 mT was applied over 21 days, starting after the last injection. Rats treated with 3NP showed significant differences in behavior, neurotrophic factor levels, oxidative stress biomarkers, and reduced neuronal density compared with neuronal controls. ELFEF improved neurological scores, enhanced neurotrophic factor levels, and reduced both oxidative damage and neuronal loss in 3NP-treated rats.